1 5
/4" x /8" Fast-Acting, Glass Tube Fuses
AGA Series
Ordering
Specify packaging, product and option code
Dimensions - mm (in)
Description
Fast-acting
1 5
/4" x /8" (6.4 x 15.9mm) physical size
Glass tube, nickel-plated brass endcap construction
Optional axial leaded version available
UL Listed product meets standard 248-14
Electrical characteristics
Rated Current % of Amp Rating Opening Time
100% 4 hours minimum
1
/4 - 10A 135% 60 minutes maximum
200% 120 seconds maximum
Agency Information
1
UL Listed, Guide JDYX, File E19180 (AGA: 0 - 3 /2A)
UL Recognized, Guide JDYX2, File E19180 (AGA: 12 - 30A)
Specifications
Part Number Voltage Rating AC Interrupting Rating* (Amps) Typical DC ColdResistance ()**
(Amps) Vac 250Vac 125Vac 32Vac Lower Upper
1
AGA- /10 250 35 10,000 - 6.186 8.370
1
AGA- /4 250 35 10,000 - 0.649 0.879
1
AGA- /2 250 35 10,000 - 0.223 0.301
3
AGA- /4 250 35 10,000 - 0.116 0.157
AGA-1 250 35 10,000 - 0.088 0.118
1
AGA-1- /2 250 100 10,000 - 0.056 0.076
AGA-2 250 100 200 - 0.038 0.052
1
AGA-2- /2 250 100 200 - 0.027 0.036
AGA-3 250 100 200 - 0.022 0.030
AGA-5 125 - 1000 - 0.013 0.017
AGA-6 125 - 1000 1000 0.011 0.015
AGA-7 125 - 1000 1000 0.008 0.011
1
AGA-7- /2 125 - 1000 1000 0.008 0.010
AGA-10 125 - 1000 1000 0.006 0.008
AGA-15*** 32 - - 1000 0.003 0.004
AGA-20*** 32 - - 1000 0.002 0.003
AGA-25*** 32 - - 1000 0.001 0.002
AGA-30*** 32 - - 1000 0.001 0.002
* Interrupting Rating: Interrupting ratings has been measured at 70%-80% power factor.
** DC Cold Resistance (Measured at <10% of rated current)
*** UR Component Recognized at 125Vac 100A IR
1011 BU-SB111165 Page 1 of 2 Data Sheet 2039TIME IN SECONDS
Time-Current Characteristic CurvesAverage Melt
CURRENT IN AMPS
CURRENT IN AMPS
Packaging Code
Packaging Code Description
BK 100 fuses packed into a cardboard carton
BK8 8000 fuses packed into a cardboard carton
Option Code
Option Code Description
B Board Washable - Hermetically sealed to withstand aqueous cleaning
The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is
intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change
design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information con-
tained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications.
Life Support Policy: Cooper Bussmann does not authorize the use of any of its products for use in life support devices or systems without the express written approval of an officer of the Company. Life sup-
port systems are devices which support or sustain life, and whose failure to perform, when properly used in accordance with instructions for use provided in the labeling, can be reasonably expected to result
in significant injury to the user.
2011 Cooper Bussmann
www.cooperbussmann.com
1011 BU-SB111165 Page 2 of 2 Data Sheet 2039
TIME IN SECONDS
1
2
3
5
10
15
20
30