Bussmann Specialty Fuse GLR Fast-Acting, Non-Rejecting & HLR Dimensional Data FUSE 0.63 (15.9mm) FUSE AND CARRIER 2.250 57.15mm Catalog Symbol: GLR (Fuse) HLR (Fuseholder) .850 .720 21.59mm Fast-Acting, Non-Rejection Style Fuse 18.29mm Ampere Rating: -15 Amperes Line Lead Voltage Rating: 300 Volts AC or less .850 C L Interrupting Rating: 10,000 Amperes 21.59mm Agency Information: GLR Fuse: Load Lead UL Listed, Std. 248-14 MOUNTING HOLE -15A/300 Vac, Guide JDYX, File E19180 .255 .870 CSA Certified, C22.2 No. 248.14, 0-10A/300 Vac 6.48mm 22.10mm Class 1422-01, File 53787 HLR Fuseholder: .635 .740 16.13mm UL Recognized, 12A, 300 Vac, Guide IZLT2, File E14853 18.80mm CSA Certified, 12A, 300 Vac, Class 6225-01, File 47235 .410 10.41mm HLR-2A: Knockout Hole Keyhole Punch UL Recognized, 15A, 300 Vac, Guide IZLT2, File E14853 CSA Certified, 15A, 300 Vac, Class 6225-01, File 47235 Time-Current Characteristic CurvesAverage Melt Electrical Ratings for Type GLR Fuses and Non-Rejection AMPERE Style Carriers RATING 100 Fuse Carrier Fuse Carrier GLR- HLR GLR-5 HLR GLR- HLR GLR-6 HLR GLR-1 HLR GLR-7 HLR GLR-1 HLR GLR-8 HLR 10 GLR-1 HLR GLR-9 HLR GLR-2 HLR GLR-10 HLR GLR-3 HLR GLR-12 HLR GLR-4 HLR GLR-15 HLR-2A General Information: 1 HLR carrier comes with 6 of 18 red insulated solid copper wire attached to the line side. Customer inserts a 18 insulated solid copper wire into load side receptacle. Order part number HLR-2A to obtain 6 of 18 black insulated solid copper wire pre-installed in a load side receptacle1 Order part number HLR-2L to obtain 6 of 18 black insulated solid copper wire packaged loose (un-installed). An alternative to the HLR fuseholder is the A fuseholder. The A fuseholder comes WITHOUT leads. The customer inserts 18 insulated solid copper wire into the line side receptacle as well as into the load side receptacle. It has the same body dimensions, utilizes the same mounting hole, and takes the same mounting clips as the HLR01 The A fuseholder is UL Recognized, 10A, 300Vac, Guide IZLT2, File E14853 and CSA Certified, 10A, 300Vac, Class 6225-01, File 47235. CURRENT IN AMPERES Fuse and knob are an integral one-piece unit. There are no replacement knobs (caps). The only controlled copy of this Data Sheet is the electronic read-only version located on the Units can be panel mounted with a separate steel clip. For the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. knockout hole (see above), choose BK/A-104. For the keyhole This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, punch type hole, choose 6374 for panels .043 to .062 thick, or without notice, to change design or construction of any products and to discontinue or limit 4909 for panels .030 to .042 thick. distribution of any products. Bussmann also reserves the right to change or update, without Do not put tension on line (rear) terminal of fuse-holder. notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. CE logo denotes compliance with European Union Low Voltage Directive Form No. GLR & HLR (50-1000 Vac, 75-1500 Vdc). Refer to Data Sheet: 8002 or contact Page 1 of 1 Bussmann Application Engineering at 636-527-1270 for more information. 5-22-02 SB02233 Data Sheet: 2032 TIME IN SECONDS .1 1 1 1.5 2 5 10 7 10 15 100 200