Positionswitch,2N/C,basic,spring-poweredinterlock Partno. LS-S02-24DFT-ZBZ/X Articleno. 106823 CatalogNo. LS-S02-24DFT-ZBZX Deliveryprogramme Basic function Position switches Safety position switches Part group reference LSZBZ/X Product range Basic units with spring-powered interlock (closed-circuit principle) Degree of Protection IP65 Features Basic device, expandable Ambient temperature C -25 - +40 Description With interlock monitoring with auxiliary release mechanism Monitoring of door position: continuous Approval Contacts N/C = Normally closed 2 NC Notes = safety function, by positive opening to IEC/EN 60947-5-1 Contact sequence Rated control voltage for magnetic drive U V 24 V DC s Housing Insulated material Connection type Screw terminal Notes Switch must never be used as a mechanical stop The operating head can be rotated manually in 90 steps without tools to suit the specified level of actuation. With the actuator inserted, the N/O contact is open and the N/C contact is closed. For degree of protection IP65, use V-M20 (206910) cable glands with connecting thread of max. 9 mm length. In the event of power failure (e.g., during commissioning), the device can be released with a screwdriver. The auxiliary release mechanism must be sealed Instructional leaflet IL 05208005Z Technicaldata General Standards IEC/EN 60947 Climatic proofing Damp heat, constant, to IEC 60068-2-78 damp heat, cyclical, to IEC 60068-2-30 Ambient temperature C -25 - +40 Mounting position As required Degree of Protection IP65 2 Terminal capacities mm 2 Solid 1 x (0.75 - 2.5) mm 2 x (0.75 - 1.5) 2 Flexible with ferrule 1 x (0.5 - 1.5) mm 2 x (0.5 - 1.5) 03/18/2016 106823 - HPL-ED2016 V20.0 EN 1 / 5Terminal screw PH1 Tightening torque for terminal screw Nm 0.9 Contacts/switchingcapacity Rated impulse withstand voltage U V AC 4000 imp Rated insulation voltage U V 400 i Overvoltage category/pollution degree III/3 Rated operational current I A e AC-15 24 V I A 6 e 220 V 230 V 240 V I A 6 e 380 V 400 V 415 V I A 4 e DC-13 24 V I A 3 e 110 V I A 0.8 e 220 V I A 0.3 e Supply frequency Hz max. 400 Short-circuit rating to IEC/EN 60947-5-1 max. fuse A gG/gL 6 Repetition accuracy mm 0.02 Rated conditional short-circuit current kA 1 Mechanicalvariables 6 Lifespan, mechanical Operations 1 x 10 Mechanical shock resistance (half-sinusoidal shock, 20 ms) Standard-action contact g 10 Operating frequency Operations/h 800 Actuation Mechanical Actuating force at beginning/end of stroke N 25/15 (plug-in/pull-out) Mechanical holding force acc. to GS-ET-19 (04/2004) XG, XW, XNG N 1700 XWA, XFG, XF N 1600 XF N 750 XNW N 1200 Electromechanical For magnet Power consumption at 120 V AC VA 8 at 230 V AC VA 11 at 24 V DC W 8 Pick-up and drop-out values x U 0.85 - 1.1 s Magnet duty factor % ED 100 DesignverificationasperIEC/EN61439 Technical data for design verification Rated operational current for specified heat dissipation I A 6 n Heat dissipation per pole, current-dependent P W 0.13 vid Equipment heat dissipation, current-dependent P W 0 vid Static heat dissipation, non-current-dependent P W 0 vs Heat dissipation capacity P W 0 diss Operating ambient temperature min. C -25 Operating ambient temperature max. C 40 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard s requirements. 03/18/2016 106823 - HPL-ED2016 V20.0 EN 2 / 5