Effective June 2017
Supersedes November 2011
Technical Data 4406
HALOGEN
HF
Pb
S505H
FREE
5 mm x 20 mm 400 Vdc/500-600 Vac time-delay fuses
Applications
Power supplies - adapters
Desktops/notebooks
TVs / Displays
Set top boxes
Lighting ballasts
Battery chargers
Printers
Game systems
Air conditioners
Product features Agency information
400 Vdc/500-600 Vac rating
S505H-XXX-R (Ferrule)
Time-delay, high breaking capacity
cURus approval: Guide JFHR2, File E56412 and Guide
5 mm x 20 mm physical size
JFHR8, File E56412
Ceramic tube with plated end cap construction
CCC: 2A-4A, Cert. No.: 2010010207395946;
Designed to IEC 60127-2, Standard, Sheet 5
5A-6.3A Cert. No.: 2010010207390567
RoHS Compliant, lead free and halogen free
CQC Approval: 8A-10A, Cert. No.: CQC10012043350
Optional axial leads available
TUV Approval: 2A-10A, Cert. No.: R50172128
PSE Approval: 1A-5A, Cert. No.: JET1641-31003-1009;
Electrical Characteristics
6.3A-10A, Cert. No: JET1641-31003-1011
1.5I 2.1I 2.75I 4I 10I
n n n n n
Min Max Min Max Min Max Min Max
S505H-V-XXX-R (Axial Leads)
Amps min. min. ms s ms s ms ms
PSE Approval: 1A-5A, Cert. No.: JET1641-31003-1010;
<1A >60 <30 >250 <80 >50 <5 >5 <150
6.3A-10A, Cert. No: JET1641-31003-1012
1A-3.15A >60 <30 >750 <80 >95 <5 >10 <150
cURus approval: Guide JFHR2, File E56412 and Guide
4A-6.3A >60 <30 >750 <80 >150 <5 >10 <150
JFHR8, File E56412
8A-10A >30 <30 >750 <80 >150 <5 >10 <150
Specifications
Typical Typical
2
Voltage Max. Voltage Interrupting Rating (A)Under DC Cold Voltage Typical Agency Approvals
1
Catalog Rating Rating 250 Max 400 Resistance Drop Value 250Vac
3 4 2 2 5 6 6 6 7
Number Vac AC DC Vac Volts Vdc (mV) I t (As) TUV CQC CCC PSE/JET cURus
S505H-500-R 250 600 400 1500 100 1500 0.507 295 0.188 x
S505H-800-R 250 600 400 1500 100 1500 0.237 189 0.632 x
S505H-1-R 250 600 400 1500 100 1500 0.14 153 1.28 X x
S505H-1.25-R 250 600 400 1500 100 1500 0.108 150 2.22 X x
S505H-1.6-R 250 600 400 1500 100 1500 0.07 125 6.78 X x
S505H-2-R 250 600 400 1500 100 1500 0.055 128 11.44 X X X x
S505H-2.5-R 250 600 400 1500 100 1500 0.04 126 24.23 X X X x
S505H-3.15-R 250 600 400 1500 100 1500 0.031 121 43.55 X X X x
S505H-4-R 250 600 400 1500 100 1500 0.019 90 38.45 X X X x
S505H-5-R 250 600 400 1500 100 1500 0.015 89 71.3 X X X x
S505H-6.3-R 250 500 400 1500 100 1500 0.011 80 111.4 X X X x
S505H-8-R 250 500 400 1500 100 1500 0.007 76 228.2 X X X x
S505H-10-R 250 500 400 1500 100 1500 0.006 72 349.5 X X X x
1. Max. Voltage rating: Base on the breaking capacity test according to UL. 3. Cold Resistance: Measure at <10% rated current.
2. - Breaking Capacity of 250 VAC/1500 A is tested by all agency approvals, test 4. Typical Voltage Drop: Voltage drop is measured under ambient 20 C with rated current
2
condition is 250 Vac, PF: 0.7-0.8.
5. Typical Pre-Arc I t: Measured at 10In DC
- Breaking Capacity of Max. voltage is tested by UL, PF:1. 6. Does not apply to axial leaded versions.
- Breaking Capacity Test of DC is tested by UL under Capacitor Bank 4800 mF 7. 600/500 Vac, 400 Vdc.
(for 400 V, 1500 A), 2400 mF (for 400 V, 500 A). S505H
Technical Data 4406
Effective June 2017 5 mm x 20 mm 400 Vdc/500-600 Vac time-delay fuses
Construction
Dimensions - mm
500-800mA
1-1.6 Amps
A (ref): 0.65 mm (0.5 A - 6.3 A), 0.80 mm (8 A-10 A)
Time-Current Curves
2 Amps & Above
1. Ceramic Tube
2. Wire Fuse Element
3. Plated Fuse Cap
4. Filler
5. Solder
6. Eyelet
Axial Leaded Versions
1. S505H-XXX-R
2. Axial Leaded Cap
Current in Amps
www.eaton.com/electronics
2
Time in Seconds