Product Information

W2E250-HL08-07

W2E250-HL08-07 electronic component of ebm papst

Datasheet
AC Axial Fan - 115VAC - 280mm x 280mm x 80mm - 175W - 2650 RPM - IP44 - Terminal ...

Manufacturer: ebm papst
Large
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 536.4581 ea
Line Total: USD 536.46

95 - Global Stock
Ships to you between
Mon. 13 May to Fri. 17 May
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
95 - WHS 1


Ships to you between Mon. 13 May to Fri. 17 May

MOQ : 1
Multiples : 1

Stock Image

W2E250-HL08-07
ebm papst

1 : USD 536.4581
3 : USD 526.1025
5 : USD 511.4812
10 : USD 475.7812

82 - WHS 2


Ships to you between Mon. 13 May to Fri. 17 May

MOQ : 1
Multiples : 1

Stock Image

W2E250-HL08-07
ebm papst

1 : USD 581.5379
10 : USD 518.1943

     
Manufacturer
Product Category
Type
Height
Depth
Width
Operating Supply Voltage
Bearing Type
Speed
Power Rating
Housing Material
Termination Style
IP Rating
Series
Hts Code
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
2100-4-7320 electronic component of ebm papst 2100-4-7320

Aluminum Electrolytic Capacitors - Snap In 1 MF CAP PLSTC 400V
Stock : 143

3412N/2ME electronic component of ebm papst 3412N/2ME

3412N2ME ebm papst dc fans & blowers thermal management
Stock : 1

4112NHH electronic component of ebm papst 4112NHH

DC Fans DC Tubeaxial Fan, 119x119x38mm, 12VDC, 152.9CFM, 13.3W, 60dBA, 5000RPM, Ball
Stock : 36

4114NXHHU electronic component of ebm papst 4114NXHHU

DC Fans Tubeaxial Fan, 119x119x38mm, 24VDC, 153CFM, 13.6W, 60dBA, 4900RPM, Ball, IP68
Stock : 1

4112N/2H4 electronic component of ebm papst 4112N/2H4

DC Fans Fan, 119x119x38mm, 12VDC, 211.8CFM, 32W, 67dBA, Speed Signal, Open Collector
Stock : 32

3500 electronic component of ebm papst 3500

AC Fans AC Tubeaxial Fan, 92x92x38mm, 115VAC, 43CFM, 8W, 35dBA, 2500RPM, Sleeve Bearing
Stock : 1

4118N/2H4PU electronic component of ebm papst 4118N/2H4PU

DC Fans Tubeaxial, 119x38mm, 48VDC, 206CFM, 34W, 67dB, 6800RPM, Ball, Speed Signal, IP68
Stock : 1

21490-1-0174 electronic component of ebm papst 21490-1-0174

Fan Accessories EBMBUS: RS485 I/F, EC-Control Series
Stock : 0

412/2P electronic component of ebm papst 412/2P

Fan: DC; axial; 12VDC
Stock : 1

412/2P-097 electronic component of ebm papst 412/2P-097

Fan: DC; axial; 12VDC
Stock : 2

Image Description
OA92AP-22-1TB electronic component of Orion OA92AP-22-1TB

AC Fans AC Fan, 92x25mm, 230VAC, 35CFM, 13W, 30dBA, 3000RPM, Dual Ball Bearing, Terminals
Stock : 75

235DL-1LP11-000 electronic component of Etri 235DL-1LP11-000

DC Fan Axial Ball Bearing 12V 4V to 13.8V 84.76CMF 34dB
Stock : 1

246DH-5LP11-000 electronic component of Etri 246DH-5LP11-000

DC Fan Ball Bearing 5V 0.43A 2.15W 3000RPM 35.3CFM 31dB Flange Mount
Stock : 1

272DH-1LP11-000 electronic component of Etri 272DH-1LP11-000

DC Fan Ball Bearing 12V 0.11A 1.32W 4000RPM 16.6CFM 28dB Flange Mount
Stock : 1

SF23092A-2092HST electronic component of Orion SF23092A-2092HST

240AC 92*92*25 SLV/BRNG 36CFM TUBE AXIAL SLEEVE BEARING
Stock : 1

OA80AP-11-1TS electronic component of Orion OA80AP-11-1TS

AC Fans AC Fan, 80x35mm, 115VAC, 31CFM, Sleeve Bearing, Terminals
Stock : 0

8500VW electronic component of ebm papst 8500VW

AC Axial Fan - 115 V - 79.5 x 79.5 x 38 mm - 34 dB - 36.0 CFM (1.01m³/min) ...
Stock : 28

4715HS-12T-B5A-A00 electronic component of MinebeaMitsumi 4715HS-12T-B5A-A00

AC Fan Axial Ball Bearing 115V 91.8CFM/105.9CFM 40dB/44dB 119 X 119 X 38mm
Stock : 1

3110MS-12W-B30-A00 electronic component of MinebeaMitsumi 3110MS-12W-B30-A00

AC Fans AC Axial Fan, 80x25mm, 115VAC, 24CFM, 6.5W, Flange Mount, Lead Wires
Stock : 0

4715MS-23T-B10-A00 electronic component of MinebeaMitsumi 4715MS-23T-B10-A00

AC Fan Axial Ball Bearing 230V 45.9CFM/49.4CFM 27dB/28dB 119 X 119 X 38mm
Stock : 1

W2E250-HL08-07 Operating instructions ebm-papst Mulfingen GmbH & Co. KG 1. SAFETY REGULATIONS AND INFORMATION Bachmhle 2 Read these operating instructions carefully before starting work on the D-74673 Mulfingen device. Observe the following warnings to prevent malfunctions or Phone +49 (0) 7938 81-0 danger to persons. Fax +49 (0) 7938 81-110 These operating instructions are to be regarded as part of the device. info1 de.ebmpapst.com The device is only to be sold or passed on together with the operating www.ebmpapst.com instructions. CONTENTS These operating instructions may be duplicated and distributed to inform about potential dangers and their prevention. 1. SAFETY REGULATIONS AND INFORMATION 1 1.1 Hazard levels for warnings 1.1 Hazard levels for warnings 1 These operating instructions use the following hazard levels to indicate 1.2 Staff qualifications 1 1.3 Basic safety rules 1 potentially hazardous situations and important safety regulations: 1.4 Voltage 1 DANGER 1.5 Safety and protective features 2 Indicates an imminently hazardous situation which will result in 1.6 Mechanical movement 2 death or serious injury if the specified actions are not taken. 1.7 Emissions 2 Compliance with the instructions is imperative. 1.8 Hot surface 2 1.9 Transport 2 WARNING Indicates a potentially hazardous situation which can result in 1.10 Storage 2 death or serious injury if the specified actions are not taken. 2. INTENDED USE 3 Exercise extreme caution while working. CAUTION 3. TECHNICAL DATA 4 Indicates a potentially hazardous situation which can result in 3.1 Product drawing 4 minor or moderate injury or damage to property if the specified 3.2 Nominal data 5 actions are not taken. 3.3 Technical description 5 3.4 Mounting data 5 NOTE 3.5 Transport and storage conditions 5 A potentially harmful situation can occur and, if not avoided, can lead to property damage. 4. CONNECTION AND STARTUP 6 4.1 Mechanical connection 6 1.2 Staff qualifications 4.2 Electrical connection 6 The device may only be transported, unpacked, installed, operated, 4.3 Connection via terminal strip 7 maintained and otherwise used by suitably qualified, trained and 4.4 Connection diagram 8 authorized technical staff. 4.5 Checking connections 9 Only authorized specialists are permitted to install the device, to carry 4.6 Switching on the device 9 out a test run and to perform work on the electrical installation. 4.7 Switching off the device 9 1.3 Basic safety rules 5. MAINTENANCE, MALFUNCTIONS, POSSIBLE 9 CAUSES AND REMEDIES The safety hazards associated with the device must be assessed again 5.1 Cleaning 10 following installation in the final product. 5.2 Safety inspection 10 The locally applicable industrial safety regulations are always to be 5.3 Disposal 10 observed when working on the device. Keep the workplace clean and tidy. Untidiness in the work area increases the risk of accidents. Note the following when working on the device: Do not perform any modifications, additions or conversions on the device without the approval of ebm-papst. 1.4 Voltage Check the device s electrical equipment at regular intervals see Chapter 5.2 Safety inspection. Replace loose connections and defective cables immediately. DANGER Electrically charged device Risk of electric shock When working on an electrically charged device, stand on a rubber mat. Item no. 10492-5-9970 ENU Change 96954 Approved 2017-10-27 Page 1 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructionsW2E250-HL08-07 Operating instructions CAUTION Do not wear any loose-fitting or dangling clothing or jewelry Electric charge on capacitor after device is switched off while working on rotating parts. Electric shock, risk of injury Protect long hair with a cap. Discharge the capacitors before working on the device. 1.7 Emissions WARNING Live terminals and connections even with device WARNING switched off Depending on the installation and operating conditions, Electric shock the sound pressure level may exceed 70 dB(A). Risk of noise-induced hearing loss Wait five minutes after disconnecting the voltage at all poles before opening the device. Take appropriate technical safety measures. Protect operating personnel with appropriate safety CAUTION equipment such as hearing protection. In the event of a fault, the rotor and the impeller will be energized Also observe the requirements of local agencies. The rotor and the impeller have basic insulation. 1.8 Hot surface Do not touch the rotor and impeller once installed. CAUTION CAUTION High temperature on motor housing The motor restarts automatically when operating voltage Risk of burns is applied, e.g. after a power failure. Risk of injury Ensure sufficient protection against accidental contact. Keep out of the device s danger zone. 1.9 Transport When working on the device, switch off the line voltage and ensure that it cannot be switched back on. NOTE Transporting the device Wait until the device comes to a stop. Transport the device in its original packaging only. 1.5 Safety and protective features Secure the device so it cannot slip, e.g. by using a lashing strip. DANGER Protective device missing and protective device not 1.10 Storage functioning Without a protective device there is a risk of serious injury, for Store the device, partially or fully assembled, in a dry place, instance when reaching into the device during operation. protected against the weather and free from vibration, in the original packaging in a clean environment. Operate the device only with a fixed protective device and guard grille. Protect the device against environmental effects and dirt until final The fixed protective device must be able to withstand the installation. kinetic energy of a fan blade that becomes detached at We recommend storing the device for no longer than one year in maximum speed. There must not be any gaps which it is order to guarantee trouble-free operation and the longest possible possible to reach into with the fingers, for example. service life. The device is a built-in component. As the operator, you Even devices explicitly intended for outdoor use are to be stored as are responsible for ensuring that the device is secured described prior to commissioning. adequately. Maintain the storage temperature, see Stop the device immediately if you notice a missing or Chapter 3.5 Transport and storage conditions. ineffective protective device. 1.6 Mechanical movement DANGER Rotating device Risk of injury to body parts coming into contact with the rotor or the impeller. Secure the device against accidental contact. Before working on the system/machine, wait until all parts have come to a standstill. WARNING Rotating device Long hair and dangling items of clothing, jewelry and the like can become entangled and be pulled into the device. Injuries can result. Item no. 10492-5-9970 ENU Change 96954 Approved 2017-10-27 Page 2 / 10 ebm-papst Mulfingen GmbH & Co. KG Bachmhle 2 D-74673 Mulfingen Phone +49 (0) 7938 81-0 Fax +49 (0) 7938 81-110 info1 de.ebmpapst.com www.ebmpapst.com Translation of the original operating instructions

Tariff Desc

FANS AND/OR BLOWERS, DC OR AC, axial OR radial OR crossflow type, having ANY one OR more of the following:
(a) sleeve OR ball OR magnetic bearings;
(c) AC operating voltage NOT less than 115 V and NOT greater than 240 V;
(d) maximum speed exceeding 1 000 RPM;
(e) diameter NOT greater than 300 mm;
(f) height NOT greater than 300 mm;
(g) length NOT greater than 300 mm,
with OR without filters
TC 17129205
EBM PAPST
ebmpapst
EBM-PAPST
ebm-papst Inc
ebm-papst Inc.
EBM-Papst Industries Inc

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted