Product Information

EA-FP ELM 5000 DUMMY PANEL KIT ALU

EA-FP ELM 5000  DUMMY PANEL KIT ALU electronic component of Elektro-Automatik

Datasheet
DUMMY PANEL KIT, ELECTRONIC DC LOAD

Manufacturer: Elektro-Automatik
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 25.2364 ea
Line Total: USD 25.24

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Mon. 27 May to Fri. 31 May

MOQ : 1
Multiples : 1
1 : USD 25.2364

     
Manufacturer
Product Category
Brand
Accessory Type
For Use With
Svhc
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
EA-ELM 5080-25 electronic component of Elektro-Automatik EA-ELM 5080-25

DC LOAD, PROG, 25A, 0-80VDC, 320W
Stock : 0

EA-EL 9080-170 B electronic component of Elektro-Automatik EA-EL 9080-170 B

DC LOAD, PROG, 170A, 0-80VDC, 1.2KW
Stock : 0

EA-IF-AB-CANO electronic component of Elektro-Automatik EA-IF-AB-CANO

DIGITAL INTERFACE MOD, ELECTRONIC LOAD
Stock : 1

EA-ELM 5200-12 electronic component of Elektro-Automatik EA-ELM 5200-12

DC LOAD, PROG, 10A, 0-200VDC, 320W
Stock : 0

38917150 electronic component of Elektro-Automatik 38917150

POWER SUPPLY, DIN-RAIL, 24V, 0.42A, 10W
Stock : 0

EA-3051B electronic component of Elektro-Automatik EA-3051B

POWER SUPPLY, 2CH, 32V, 5A, ADJUSTABLE
Stock : 1

EA-IF-C2 electronic component of Elektro-Automatik EA-IF-C2

INTERFACE CAN (EA-PSI/BCI 800 R); For Use With:EA-IF Series; Accessory Type:Interface Card; Product Range:-; SVHC:No SVHC (27-Jun-2018)
Stock : 0

EA-4000 B-4,5 electronic component of Elektro-Automatik EA-4000 B-4,5

POWER SUPPLY, 5CH, 32V, 5A, ADJUSTABLE
Stock : 0

EA-IF-AB-PNET2P electronic component of Elektro-Automatik EA-IF-AB-PNET2P

DIGITAL INTERFACE MOD, ELECTRONIC LOAD
Stock : 0

35320148 electronic component of Elektro-Automatik 35320148

35320148
Stock : 0

Image Description
F-596-C electronic component of Waldom F-596-C

4 X 1/2 PAN HEAD SCREW
Stock : 1

RVUVK105CH020BW-F electronic component of Taiyo Yuden RVUVK105CH020BW-F

CAP, HIGH FREQ, 0402, 50V, C0H
Stock : 1

MPZ2012-KIT electronic component of TDK MPZ2012-KIT

C216-005
Stock : 1

RVEVK105CH3R9JW-F electronic component of Taiyo Yuden RVEVK105CH3R9JW-F

CAP, HIGH FREQ, 0402, 16V, C0H
Stock : 1

RMJMK063BJ224MP-F electronic component of Taiyo Yuden RMJMK063BJ224MP-F

CAP 0.22UF 6.3VDC X5R 20% SMD 0201
Stock : 1

RMUMK105CG3R9CV-F electronic component of Taiyo Yuden RMUMK105CG3R9CV-F

CAP, MLCC, 0402, 50V, C0G, 3.9
Stock : 1

OSTOQ025350 electronic component of On Shore Technology OSTOQ025350

Conn Shrouded Header (4 Sides) HDR 2 POS 5.08mm Solder ST Thru-Hole
Stock : 1

F-465-C electronic component of Waldom F-465-C

F465C waldom
Stock : 1

F-524-C electronic component of Waldom F-524-C

F524C waldom
Stock : 1

F-040-C electronic component of Waldom F-040-C

F040C waldom
Stock : 1

EA-ELR 5000 320 W - 3200 W Charges lectroniques DC programmables avec rinjection dnergie Programmable electronic DC loads with energy recovery A B C D EA-ELR 5000 Rack E U I P OVP OCP OPP OTP 19 LAN F G Charge DC multivoies Multi-channel DC load Rinjection de lnergie dalimentation DC sur le Energy recovery of the supplied DC energy into the secteur local grid Rack 19 6U jusqu 10 modules de charge spars 19 6U rack for up to 10 separate load modules H Puissances dentre : jusqu 0...320 W par module Input power ratings: up to 0...320 W per module Tensions dentre : 0...80 V ou 0...200 V Input voltages: 0...80 V or 0...200 V Courants dentre : 0...12 A ou 0...25 A Input currents: 0...12 A or 0...25 A I Contrle numrique base de micro-contrleur Controller based digital control Ecran TFT tactile bilingue (DE/EN) Bilingual TFT touch panel (DE/EN) Gnrateur de squences Sequence generator J Interface Ethernet/LAN intgre Ethernet/LAN interface built-in Commandes de langage SCPI et Modbus acceptes SCPI command language and ModBus supported Gnralits General La nouvelle srie EA-ELR 5000 a t conue pour configurer une charge The new series EA-ELR 5000 was designed to configure a multi-channel lectronique DC multivoies. Dans un rack ddi aux systmes 19, il est electronic DC load. In a rack for 19 systems, up to ten DC load units with possible dinstaller jusqu dix units de charge DC avec une puissance no- 320 W nominal power each can be installed. The modular units operate minale pour chacune de 320 W. Les units modulaires fonctionnent spa- separately from each other, but require the rack as it contains the energy rment les unes des autres, mais ncessitent le rack puisquil intgre lin- recovering DC-AC inverter. The modules are also extendable. Parallel con- verseur DC-AC de rinjection dnergie. Les modules sont aussi extensibles. nection on the DC inputs of the module is possible. The load modules come Les modules de charge existent en deux catgories de tension 80 V et 200 in two voltage variants, 80 V and 200V, and incorporate the common reg- V, et intgrent les modes communs de rgulation tension constante (CV), ulation modes constant voltage (CV), constant current (CC) and constant courant constant (CC) et puissance constante (CP). power (CP). La fonction de rinjection dnergie convertit lnergie dalimentation DC The energy recovery function inverts the supplied DC energy into a syn- en un courant sinusodal synchrone et le rinjecte sur le secteur. Cela rduit chronous sine current and feeds it back into the local grid. This reduces the la dissipation de chaleur habituelle au minimum et conomise de lner- usual heat dissipation to a minimum and saves energy costs at the same gie simultanment. Lcran couleur TFT tactile propose une utilisation ma- time. The colour TFT touch panel offers an intuitive kind of manual oper - nuelle trs intuitive. ation. 114 EA-Elektro-Automatik 2016, Sujet modifications sans pravis, sous rserve derreurs typographiques / Subject to modification without notice, errors and omissions exceptedCharges lectroniques DC programmables avec rinjection / Programmable electronic DC loads, recovering EA-ELR 5000 320 W - 3200 W Dotes dun port Ethernet par dfaut, les units de charge peuvent tre in- Equipped with an Ethernet port by default, the load units can be easily in- tgres simplement dans un rseau dinstruments LAN avec un switch stan- tegrated into a network of LAN devices with a standard 1U 19 switch. Ex- dard 1U 19. Le contrle externe est possible via le logiciel Windows inclus ou ternal control is possible via an included Windows software or via custom via des applications personnalises cres dans LabView ou un autre IDE. Les applications created in LabView or other IDEs. The commonly known com- protocoles de communication communment connus SCPI et ModBus sont munication protocols SCPI and ModBus are supported. accepts. Puissances, tensions, courants Power ratings, voltages, currents Il existe deux modles de charge disponibles, lun avec une tension dentre There are two load models available. One for max. 80 V DC input voltage A de 80 V DC et lautre de 200 V . Les deux modles possdent une puissance and one for max. 200 V. Both models have a max. power of 320 W, while max de 320 W, le modle 80 V peut atteindre un courant jusqu 25 A et le the 80 V model can take up to 25 A and the 200 V can take up to 12 A. By in- modle 200 V jusqu 12 A. En installant jusqu 10 units de ces modules stalling up to 10 units of these load modules into a single rack it is possible B de charge dans un mme rack, il est possible dtendre la puissance 3200 to extend the power to 3200 W max. W max. C Construction Construction Le rack utilis pour assembler les modules de charge, est conu avec une The rack, which is used to hold the load modules, is designed with 19 largeur de 19 et une hauteur de 6U, pour une profondeur de 480 mm. Cela width and 6U height, while having an installation depth of 480 mm. This le rend idal pour une utilisation dans des chssis 19 de diffrentes tailles. makes it ideal for use in 19 cabinets of various sizes. D Alimentation Supply Le rack peut tre utilis sur une installation fixe 230 V AC (10%) et prot - The rack can be operated on a fixed installation with 230 V AC (10%) and E ge par fusible 16 A. La fonction de rinjection ncessite de toujours avoir 16A fused. The recovery feature requires to always have sufficient devices suffisamment dappareils sur le rseau pour consommer lnergie rinjec - on the grid to consume the backfed energy. te. La connexion secteur peut tre quipe dune unit de surveillance The grid connection can be equipped with a supervision unit ENS2 (see F ENS2 (voir page 175), qui est disponible en option, interchangeable et page 175) which is optionally available, retrofittable and modular. modulaire. Avec cette option installe, la connexion secteur sera toujours With this option installed, the grid connection will always be three-phase triphase (L1, L2, L3, N, PE). (L1, L2, L3, N, PE). G Rinjection dnergie Energy recovery La fonctionnalit la plus importante de ces charges lectroniques est que The most important feature of these electronic loads is that the AC input, lentre AC, ex : la connexion secteur, est galement utilise comme sortie i.e. grid connection, is also used as output for the recovery of the supplied H pour la rinjection de lnergie DC dalimentation, laquelle sera convertie DC energy, which will be converted with an efficiency of approximately avec un rendement denviron 93%. Cette rinjection dnergie permet des 93%. This way of energy recovery helps to lower energy costs and avoids cots relatifs lnergie plus faibles et dviter des systmes de refroidisse- expensive cooling systems, such as required for conventional electronic I ment trop onreux, comme ce qui est ncessaire avec les charges lectro- loads which convert the DC input energy into heat. niques conventionnelles qui convertissent lnergie de lentre DC en cha- Principle view: leur. Schma de principe : J Recovery 95% = 2.85 kW Rinjection 95% = 2.85 kW E.U.T AC e.g. power supply DC Objet sous AC test, ex. un DC alimentation Consumer e.g. 3 kW Appareil de consommation ex. 3 kW Operation of these recovering loads in terms of power generation is not in- Le fonctionnement de ces charges rinjection en terme de gnration de tended. There is an additional supervision unit (automatic isolation unit, puissance nest pas prvu. Une unit de surveillance additionnelle est dis- ENS) available for optional installation and to achieve additional safety of ponible en option (unit disolement automatique, ENS) dans le but dob- persons and equipment, especially when running the so-called isolated op- tenir une scurit supplmentaire pour lquipement et lutilisateur, sp- eration. cialement pour le lancement de fonctionnement dit isol. En fonction de Regardless of whether the user has installed that supervision unit or not, linstallation ou non de lunit de surveillance par lutilisateur, les appareils the devices feature a simple and non-redundant switch-off function for the disposent dune fonction de dsactivation simple et non rptitive dans le case of an interruption in the grid connection cable. They supervise AC volt- cas dune interruption de la liaison secteur. Ils surveillent la tension AC et la age and frequency and will automatically switch off the inverter block in frquence, puis dsactiveront automatiquement le bloc inverseur en cas de case upper or lower limits are exceeded. dpassement des limites haute ou basse. EA-Elektro-Automatik 2016, Sujet modifications sans pravis, sous rserve derreurs typographiques / Subject to modification without notice, errors and omissions excepted 115

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted