Product Information

FLK-TI27 60HZ

FLK-TI27 60HZ electronic component of Fluke

Datasheet
INDUST COMM THERMAL IMAGER 60HZ

Manufacturer: Fluke
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)
N/A

Obsolete
Availability Price Quantity
0 - WHS 1

MOQ : 1
Multiples : 1
1 : USD 7128.0236
N/A

Obsolete
     
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Packaging
Brand
Factory Pack Quantity :
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
1273185 electronic component of Fluke 1273185

HEAVY DUTY TEST LEAD SET
Stock : 1

1547885 electronic component of Fluke 1547885

Fluke METER CASE,LEATHER,LARGE
Stock : 1

1576734 electronic component of Fluke 1576734

Fluke FLUKEVIEW FORMS WITH CABLE FOR USE WITH 18X, 28X DMMS
Stock : 1

1610115 electronic component of Fluke 1610115

AC280 Suregrip Hook Clips
Stock : 0

1LAC-A electronic component of Fluke 1LAC-A

LOW VOLTAGE DETECTOR AMERICAS PACIFIC AVAILABLE IN 12 PA
Stock : 0

114519 electronic component of Fluke 114519

AC/DC CURRENT PROBE, SCOPEMETER(R)
Stock : 1

1503 electronic component of Fluke 1503

Insulation Resistance Testers
Stock : 0

1630 electronic component of Fluke 1630

Fluke 1630 Earth Ground Clamp Meter
Stock : 1

190-102/AM electronic component of Fluke 190-102/AM

Oscilloscope (DSO) + DMM - 2 Ch, 100 MHz -- 6" Color TFT LCD -- 8 bit, 1.25Gs/S Portable Scopemeter® ...
Stock : 1

1623-2-KIT electronic component of Fluke 1623-2-KIT

Basic GEO Earth Ground Tester Kit
Stock : 1

Image Description
FLK-100-CLKT electronic component of Fluke FLK-100-CLKT

Thermal Imaging Cameras 4 IN (100MM) C-RANGE IR WINDOW, KWIK TWIST
Stock : 1

P5605 electronic component of PEAKTECH P5605

Infrared camera; Equipment: microSD memory card, case; -20÷300°C
Stock : 2

FLK-050-CLKT electronic component of Fluke FLK-050-CLKT

Fluke 2 IN (50MM) C-RANGE IR WINDOW, KWIK TWIST
Stock : 2

FLK-075-CLKT electronic component of Fluke FLK-075-CLKT

Thermal Imaging Cameras 3 IN (75MM) C-RANGE IR WINDOW, KWIK TWIST
Stock : 8

T-SCAN 750 electronic component of Amphenol T-SCAN 750

Thermal Imaging Cameras Temperature Scanning Entry System
Stock : 2

TR-EVO-T33-USB electronic component of Terabee TR-EVO-T33-USB

Thermal Imaging Cameras TeraRanger Evo Thermal 33 USB
Stock : 0

101020893 electronic component of Seeed Studio 101020893

Thermal Imaging Cameras Grove - Thermal Imaging Camera - MLX90621 BAA 16x4 IR Array with 25 FOV
Stock : 1

TR-EVO-T90-UART electronic component of Terabee TR-EVO-T90-UART

Thermal Imaging Cameras TeraRanger Evo Thermal 90 UART
Stock : 5

IRW-4C electronic component of Teledyne FLIR / Extech IRW-4C

Thermal Imaging Cameras FLIR IRW Aluminum InfraRed Window 4" (O.D. 5.01 /127mm)
Stock : 11

CA 1900 electronic component of Chauvin Arnoux CA 1900

Infrared camera; LCD 2,8\; -15÷50°C; Accur: ±0,5°C; 60mK; 4.1mrad
Stock : 1

Fluke Industrial Thermal Imagers Models: Ti32, Ti29 and Ti27. Three models specifically for industrial and electrical applications. Technical Data The P3 Series: Superior, not Superfluous. Fluke is how other tools are measured. The greatest technological advancement in thermography may be how Fluke has made it so simple to capture images and analyze data right out of the box. Superior image quality Industry-leading thermal sensitivity and spatial resolution combined with a high definition display, creates the sharp- est images in the industry. One-handed, easy-to-use interface With just a push of your thumb, go from one-handed manual smart focus to adding picture-in-picture and even add voice comments. Torture tested Before a Fluke goes into your hands, we drop it from ours. Only Fluke thermal imagers are designed from the inside Ti27 Ti29 Ti32 out to withstand a 6.5 ft drop. 240x180 IR 280x210 IR 320x240 IR Patented Fluke IR-Fusion resolution resolution resolution 43,200 total 58,800 total 76,800 total (Picture-in-picture and auto blending) IR pixels IR pixels IR pixels Precision visible and IR image alignment allows Fluke to offer the only on-camera blended infrared and visible image to better diagnose issues. Made in the U.S.A. of U.S. and Interchangeable lenses non U.S. parts Interchangeable wide-angle and IR-Fusion compatible telephoto lenses to cover any application. Fluke. Not just infrared, infrared you can use. Industrial Mechanical, electromechanical and general building maintenance. Not all fusion is created equal Dont be fooled by imitators. No other manufacturer Patented Fluke IR-Fusion Technology can boast on-camera blending. Compare the images. Only Fluke has mastered the ability to create the More than picture in picture industrys only transparent, perfectly blended and Process Infrared images alone can be difficult to under- aligned visible and infrared images. Refractory insulation, stand, which is why Fluke pioneered IR-Fusion, tank and vessel levels, Fluke Competitor steam systems and traps, a revolutionary marriage of visible and infrared pipes and valves, etc. images never before seen in commercial or industrial thermal imagers. Automatically capturing a visible image with every infrared image allows to you always know exactly what youre looking at. Electrical Unbalanced loads, overloaded systems, wiring mistakes or component failure, etc.Detailed specifications Ti32 Ti29 Ti27 Temperature Temperature measurement range -20 C to +600 C (-4 F to +1112 F) (not calibrated below -10 C) Temperature measurement 2 C or 2 % (at 25 C nominal, whichever is greater) accuracy On-screen emissivity correction Yes On-screen reflected background Yes temperature compensation On-screen transmission correction Yes Imaging performance Image capture frequency 9 Hz refresh rate or 60 Hz refresh rate depending upon model variation Detector type Focal Plane Array, uncooled Focal Plane Array, uncooled Focal Plane Array, uncooled microbolometer, 320 x 240 pixels microbolometer, 280 x 210 pixels microbolometer, 240 x 180 pixels Thermal sensitivity (NETD) 0.045 C at 30 C target temp. (45 mK) 0.05 C at 30 C target temp (50 mK) Total pixels 76,800 58,800 43,200 Infrared spectral band 7.5 m to 14 m (long wave) Visual (visible light) camera Industrial performance 2.0 megapixel Minimum focus distance 45 cm (approx. 18 in) Standard infrared lens type Field of view 23 x 17 Spatial resolution (IFOV) 1.25 mRad 1.43 mRad 1.67 mRad Minimum focus distance 15 cm (approx. 6 in) Optional telephoto infrared lens type Field of view 11.5 x 8.7 Spatial resolution (IFOV) 0.63 mRad 0.72 mRad 0.84 mRad Minimum focus distance 45 cm (approx. 18 in) Optional wide-angle infrared lens type Field of view 46 x 34 Spatial resolution (IFOV) 2.50 mRad 2.86 mRad 3.34 mRad Minimum focus distance 7.5 cm (approx. 3 in) Focus mechanism Manual, one-handed Smart Focus capability Image presentation Palettes Standard Ironbow, Blue-Red, High Contrast, Amber, Amber Inverted, Hot Metal, Grayscale, Grayscale Inverted Ultra Contrast Ironbow Ultra, Blue-Red Ultra, High Contrast Ultra, Amber Ultra, Amber Inverted Ultra, Hot Metal Ultra, Grayscale Ultra, Grayscale Inverted Ultra Level and span Smooth auto-scaling and manual scaling of level and span Fast auto toggle between manual Yes and auto modes Fast auto-rescale in manual mode Yes Minimum span (in manual mode) 2.5 C (4.5 F) Minimum span (in auto mode) 5 C (9 F) IR-Fusion information Automatically aligned (parallax Yes corrected) visual and IR blending Picture-In-Picture (PIP) Three levels of on-screen IR blending displayed in center of LCD Full screen infrared Three levels of on-screen IR blending displayed on LCD Color alarms (temperature alarms) High-temperature alarm (user-selectable) Voice annotation 60 seconds maximum recording time per image reviewable playback on imager Image capture and data storage The Ti32, Ti29 and Ti27 allow users to adjust palette, blending, level, span, IR-Fusion mode, emissivity, and reflected background temperature compensation, and transmission correction on a captured image before it is stored Image capture, review, save One-handed image capture, review, and save capability mechanism Storage medium SD Memory Card (2 GB memory card will store at least 1200 fully radiometric (.is2) IR and linked visual images each with 60 seconds voice annotations, or 3000 basic bitmap (.bmp) images, or 3000 jpeg (.jpeg) images transferrable to PC via included multi-format USB card reader File formats Non-radiometric (.bmp) or (.jpeg) or fully-radiometric (.is2) No analysis software required for non-radiometric (.bmp and .jpeg) files Export file formats w/SmartView BMP, DIB, GIF, JPE, JFIF, JPEG, JPG, PNG, TIF, and TIFF software Memory review Thumbnail view navigation and review selection 2 Fluke Corporation Ti32, Ti29 and Ti27 Industrial Thermal Imagers

Tariff Desc

9027.10.00 Instruments and apparatus for physical or chemical analysis (for example, polarimeters, refractometers, spectrometers, gas or smoke analysis apparatus); instruments and apparatus for measuring or checking viscosity, porosity, expansion, surface tension or the like; instruments and apparatus for measuring or checking quantities of heat, sound or light (including exposure meters); microtomes.
FLUKE CALIBRATION
Fluke Electronics
FLUKE NETWORKS

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted