Product Information

KIT-FC6A-P16-R

KIT-FC6A-P16-R electronic component of Idec

Datasheet
Controllers FC6A Plus 16IO Starter Kit

Manufacturer: Idec
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 766.7231 ea
Line Total: USD 766.72

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Thu. 23 May to Wed. 29 May

MOQ : 1
Multiples : 1
1 : USD 978.8872
10 : USD 899.9701

0 - WHS 2


Ships to you between Wed. 29 May to Fri. 31 May

MOQ : 1
Multiples : 1
1 : USD 805.6313
10 : USD 803.0862
25 : USD 796.2192
50 : USD 796.2192
100 : USD 796.2192
250 : USD 796.2192
500 : USD 796.2192
1000 : USD 796.2192
2500 : USD 796.2192

     
Manufacturer
Product Category
Brand
No. Of Inputs
No. Of Outputs
Kit Contents
Product Range
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
AB6M-BK2-S electronic component of Idec AB6M-BK2-S

Switch Access Round Button Push Button Switch
Stock : 5

AB6Q-M1P-G electronic component of Idec AB6Q-M1P-G

Switch Push Button N.O./N.C. SPDT Square Button 1A 250VAC 250VDC Momentary Contact Quick Connect/Solder Panel Mount
Stock : 25

ABD101N-BGR electronic component of Idec ABD101N-BGR

Switch Push Button N.C. SPST Flush Round Button 10A 440VAC 220VDC Momentary Contact Screw Panel Mount
Stock : 1

AB6M-M1-W electronic component of Idec AB6M-M1-W

Switch Push Button N.O./N.C. SPDT Round Button 1A 250VAC 250VDC Momentary Contact Quick Connect/Solder Panel Mount
Stock : 5

AB8M-M1-G electronic component of Idec AB8M-M1-G

Switch Push Button N.O./N.C. SPDT Round Button 1A 250VAC 250VDC Momentary Contact Solder Tab Panel Mount
Stock : 1

ABD311N-G electronic component of Idec ABD311N-G

Switch Push Button N.O./N.C. DPST Mushroom Button 10A 440VAC 220VDC Momentary Contact Screw Panel Mount
Stock : 0

ABFW110-G electronic component of Idec ABFW110-G

Switch Push Button N.O. SPST Recessed Round Button 10A 440VAC 220VDC 745.7VA Momentary Contact Screw Panel Mount
Stock : 1

ABFW211-B electronic component of Idec ABFW211-B

Switch Push Button N.O./N.C. DPST Extended Button 10A 440VAC 220VDC 745.7VA Momentary Contact Screw Panel Mount
Stock : 1

AB6E-4BV02PRM electronic component of Idec AB6E-4BV02PRM

Emergency Stop Switches / E-Stop Switches Emergency Stop Unibody
Stock : 0

ABFD411NUG electronic component of Idec ABFD411NUG

Pushbutton Switches 30mm Mom 65mm Deep 1NO 1NC Grn
Stock : 0

Image Description
ROMI CHASSIS KIT - BLACK electronic component of Pololu ROMI CHASSIS KIT - BLACK

Wheeled chassis; POLOLU Romi; black; 3÷6VDC; Mot.qty:2
Stock : 1

2701137 electronic component of Phoenix Contact 2701137

Controllers nLC-OP1-LCD-032-4X20 USER INTERFACE
Stock : 1

2862990 electronic component of Phoenix Contact 2862990

Controllers IB IL PD GNC-PAC
Stock : 1

E53-Q electronic component of Omron E53-Q

Controllers Temp. Voltage Module
Stock : 8

E53-Q4 electronic component of Omron E53-Q4

Relay/Pulse , SPST, 5 A/NPN, 24 VDC
Stock : 1

Hot Y92A-48B electronic component of Omron Y92A-48B

Front hard protective cover square - 50.5 mm x 50.5 mm x 16 mm - Plastic
Stock : 1

KL1104 electronic component of Beckhoff KL1104

Industrial module: digital input; 24VDC; -25÷60°C; IP20; IN:4
Stock : 8

79453771 electronic component of Crouzet 79453771

Controllers JOINT TORIQUE DE MINI ELECTROVANNE 81519
Stock : 27

FW-STR1P-P electronic component of F&F FW-STR1P-P

Blinds controller; F&Wave; IP20; 100÷265VAC; flush mount; 100m; 1W
Stock : 1

PCZ-21 electronic component of Zamel PCZ-21

Power stand; EXTA LIFE; 6/24VAC; 6÷24VDC; RCZ-21
Stock : 1

B-1722(4) FC6A SERIES Users ManualSAFETY PRECAUTIONS Read theFC6A Series MICROSmart Users Manua to ensure correct operation before starting installation, wiring, operation, maintenance, and inspection of the FC6A Series MICROSmart. All FC6A Series MICROSmart modules are manufactured under IDECs rigorous quality control system, but users must add a backup or failsafe provision to the control system when using the FC6A Series MICROSmart in applications where heavy damage or personal injury may be caused, in case the FC6A Series MICROSmart should fail. In this manual, safety precautions are categorized in order of importance: Warning Warning notices are used to emphasize that improper operation may cause severe personal injury or death. The FC6A Series MICROSmart is not designed for use in applications requiring a high degree of reliability and safety. The FC6A Series MICROSmart should not be used for such applications. When using the FC6A Series MICROSmart in applications (not described above) that require a high degree of reliability in terms of functionality and precision, appropriate measures such as failsafe mechanisms and redundant mechanisms must be taken for the system containing the FC6A Series MICROSmart. The following are specific examples. Emergency stop and interlocking circuits must be configured outside the FC6A Series MICROSmart. If relays or transistors in the FC6A Series MICROSmart output circuits should fail, outputs may remain at on or off state. For output signals which may cause serious accidents, configure monitor circuits outside the FC6A Series MICROSmart. The FC6A Series MICROSmart self-diagnostic function may detect internal circuit or program errors, stop programs, and turn outputs off. Configure circuits so that the system containing the FC6A Series MICROSmart is not jeopardized when outputs turn off. Turn off power to the FC6A Series MICROSmart before installation, removal, wiring, maintenance, and inspection of the FC6A Series MICROSmart. Failure to turn power off may cause electrical shocks or fire hazard. Special expertise is required to install, wire, program, and operate the FC6A Series MICROSmart. People without such expertise must not use the FC6A Series MICROSmart. Install the FC6A Series MICROSmart according to the instructions described in theFC6A Series MICROSmart Users Manua. Improper installation will result in falling, failure, or malfunction of the FC6A Series MICROSmart. Caution notices are used where inattention might cause personal injury or damage to equipment. Caution The FC6A Series MICROSmart is designed for installation in a cabinet. Do not install the FC6A Series MICROSmart outside a cabinet. Install the FC6A Series MICROSmart in environments described in theFC6A Series MICROSmart Users Manua. If the FC6A Series MICROSmart is used in places where the FC6A Series MICROSmart is subjected to high-temperature, high-humidity, condensation, corrosive gases, excessive vibrations, or excessive shocks, then electrical shocks, fire hazard, or malfunction will result. The environment for using the FC6A Series MICROSmart isPollution degree 2 Use the FC6A Series MICROSmart in environments of pollution degree 2 (according to IEC 60664-1). Prevent the FC6A Series MICROSmart from falling while moving or transporting the FC6A Series MICROSmart, otherwise damage or malfunction of the FC6A Series MICROSmart will result. Wiring must use lead sizes that are appropriate for the applied voltage and current. Terminal screws must be tightened with the prescribed tightening torque. Prevent metal fragments and pieces of wire from dropping inside the FC6A Series MICROSmart housing. Put a cover on the FC6A Series MICROSmart modules during installation and wiring. Ingress of such fragments and chips may cause fire hazard, damage, or malfunction. Use a power supply of the rated value. Use of a wrong power supply may cause fire hazard. Use an IEC 60127-approved fuse on the power line outside the FC6A Series MICROSmart. This is required when equipment containing the FC6A Series MICROSmart is destined for Europe. Use an IEC 60127-approved fuse on the output circuit. This is required when equipment containing the FC6A Series MICROSmart is destined for Europe. Use an EU-approved circuit breaker. This is required when equipment containing the FC6A Series MICROSmart is destined for Europe. Make sure of safety before starting and stopping the FC6A Series MICROSmart or when operating the FC6A Series MICROSmart to force outputs on or off. Incorrect operation of the FC6A Series MICROSmart may cause machine damage or accidents. Do not connect the ground wire directly to the FC6A Series MICROSmart. Connect a protective ground to the cabinet containing the FC6A Series MICROSmart using an M4 or larger screw. This is required when equipment containing the FC6A Series MICROSmart is destined for Europe. Do not disassemble, repair, or modify the FC6A Series MICROSmart modules. The FC6A Series MICROSmart contains electronic parts and batteries. When disposing of the FC6A Series MICROSmart, do so in accordance with national and local regulations. Preface-1 FC6A SERIES MICROSMART USERS MANUAL FC9Y-B1722

Tariff Desc

8473.30.00 - Parts and accessories of the machines of 8471 AUTOMATIC DATA PROCESSING MACHINES AND UNITS THEREOF; MAGNETIC OR OPTICAL READERS, MACHINES FOR TRANSCRIBING DATA ONTO DATA MEDIA IN CODED FORM AND MACHINES FOR PROCESSING SUCH DATA, NOT ELSEWHERE SPECIFIED OR INCLUDED: Free
62 No .Cards (including network, sound, video, IDE, SCSI, and other similar cards)

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted