Product Information

ATO-125-B1I-D16

ATO-125-B1I-D16 electronic component of Lem

Datasheet
CURRENT TRANSFORMER, 125A, PANEL; Input Current:125A; Turns Ratio:1:1000; Frequency Min:-; Frequency Max:-; Transformer Mounting:Panel; Product Range:ATO Series; SVHC:No SVHC (12-Jan-2017)

Manufacturer: Lem
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)

1: USD 62.9761 ea
Line Total: USD 62.98

0 - Global Stock
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
0 - WHS 1


Ships to you between Fri. 10 May to Thu. 16 May

MOQ : 1
Multiples : 1
1 : USD 62.9761
5 : USD 54.194
10 : USD 47.074
25 : USD 44.8497

     
Manufacturer
Product Category
Turns Ratio
Brand
Input Current
Transformer Mounting
Product Range
Svhc
LoadingGif

Notes:- Show Stocked Products With Similar Attributes.
Image Description
CKSR 25-NP electronic component of Lem CKSR 25-NP

SENSOR CURRENT FLUX 25A AC/DC
Stock : 0

CAS 50-NP electronic component of Lem CAS 50-NP

SENSOR CURRENT FLUX 50A AC/DC
Stock : 2

AT150B420L electronic component of Lem AT150B420L

CURRENT TRANSDUCER, 150A, CURRENT O/P
Stock : 0

AT100B420L electronic component of Lem AT100B420L

CURRENT TRANSDUCER, 100A, CURRENT O/P
Stock : 0

DHR 600 C10 electronic component of Lem DHR 600 C10

Current Transducer,600A, 0-10V O/P
Stock : 0

DHR 1000 C420 electronic component of Lem DHR 1000 C420

Current Transducer,1000A, 4-20Ma O/P
Stock : 0

AT20B420L electronic component of Lem AT20B420L

CURRENT TRANSDUCER, 20A, CURRENT O/P
Stock : 0

AT50B10 electronic component of Lem AT50B10

CURRENT TRANSDUCER, 50A, VOLTAGE O/P
Stock : 0

HAS300-S electronic component of Lem HAS300-S

Current Sensors Through Hole RoHS
Stock : 1

LAH100-P electronic component of Lem LAH100-P

Current Sensors Through Hole RoHS
Stock : 12

Image Description
Hot 56T100C electronic component of Murata 56T100C

Current Transformers 20-37mH at 1V 50kHz 10A 100CT turns
Stock : 1

AC1100 electronic component of Talema AC1100

Current transformer; Series: AC; 100A; Trans:1000:1; 100O; 1000mVA
Stock : 1

TI-EE16-0096 electronic component of Feryster TI-EE16-0096

Transformer: impulse; for power supplies; 2W; Works with: LNK362P
Stock : 0

TSZZ7/015M electronic component of Indel TSZZ7/015M

Transformer: encapsulated; 7VA; 230VAC; 24V; 0.29A; Mounting: PCB
Stock : 20

PB0027NL electronic component of Pulse PB0027NL

Current Transformers SMD Current Sense 22400uH 2.9Ohms
Stock : 1

TEZ4/D230/7.5V electronic component of Breve Tufvassons TEZ4/D230/7.5V

Transformer: encapsulated; 4VA; 230VAC; 7.5V; 533.3mA; IP00; 150g
Stock : 43

44094 electronic component of Myrra 44094

Transformer: encapsulated; 1.5VA; 230VAC; 15V; 15V; 50mA; 50mA
Stock : 50

HCT204ATN electronic component of Hop Tech HCT204ATN

Current Transformers 19.5*18.5*18.3 RoHS
Stock : 77

Hot CST25-0200 electronic component of Triad CST25-0200

Current Transformers PCB Curr Sense Xfmr 1:200,50-500KHz
Stock : 1

TSZZ2.5/012M electronic component of Indel TSZZ2.5/012M

Transformer: encapsulated; 2.5VA; 230VAC; 18V; 18V; 0.06A; 0.06A
Stock : 0

SPLIT CORE CURRENT TRANSFORMER ATO Series Ref: ATO-125-B1I-D16 ATO series is a split core current transformer for the electronic measurement of AC waveform current with galvanic separation between the primary circuit (power) and the secondary circuit (measurement). ATO series is an ideal current transformer for new Smart-Grid applications, in which ratio error and phase displacement are fully tested with IEC 61869 standards accordance. Accuracy Class 3 I P I OUT C L R L A B C D E mm 56.1 19.3 40.8 25.8 33.2 16 Features Applications Split-core current transformer Hybrid inverter (Home Energy Storage) Rated primary current: 125 A Power metering: current measurement for active power calculation Application up to 600 V CAT III PD2, basic insulation Building sub-metering: energy efficiency monitoring, Accuracy class 3 (IEC 61869-2) consumption analysis and cost allocation Current output: 125 mA at I Pr Power quality monitoring: electrical loads and distribution 16 mm sensing aperture system equipment 1 m output cable Distributed measurement systems Ambient temperature 20 C +70 C Condition monitoring (e.g. Motor loads such as conveyers, Very low cost solution pumps). Slot for attaching the C.T. on the primary with plastic tie Standards DIN rail adapter (optional). IEC 61010-1: 2010 Advantages IEC 61010-031 ed1.1: 2012 No interruption of electricity during installation on insulated IEC 61869-1 ed1.0: 2007 conductors IEC 61869-2: ed1.0: 2012 Quick, non-intrusive and easy setup IEC 61869-6: draft 2016 Provide a calibrate output. IEC 61869-10: draft 2016 UL 508: 2013. N52.C3.36.000.0 Page 1/10 28March2016/version 0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com LEM City answers the demand for an accurate, reliable and easy to install energy sensor for future Smart Cities. www.lemcity.com SPLIT CORE CURRENT TRANSFORMER ATO Series Absolute maximum ratings Parameter Symbol Unit Value Primary conductor temperature T C 100 B Stresses above these ratings may cause permanent damage. Exposure to absolute maximum ratings for extended periods may degrade reliability. UL 508: Ratings and assumptions of certification File E189713 Volume: 2 Section: 8 Standards CSA C22.2 NO. 14-10 INDUSTRIAL CONTROL EQUIPMENT - Edition 11 - Revision Date 2011/08/01 UL 508 STANDARD FOR INDUSTRIAL CONTROL EQUIPMENT - Edition 17 - Revision Date 2013/10/16 For use only in complete equipment where the acceptability of the combination is determined by UL.LLC. Ratings Parameter Symbol Unit Value Primary involved potential V AC/DC 1000 Max surrounding air temperature T C 70 A Primary current I A 125 P Conditions of acceptability When installed in the end-use equipment, consideration shall be given to the following: - These devices must be mounted in a suitable end-use enclosure. - The terminals have not been evaluated for field wiring - The products shall be used in a pollution degree 2 - Based on results of temperature test, in the end-use application a maximum of 100 C can not be exceeded on the primary conductor. Marking Only those products bearing the UL or UR Mark should be considered to be Listed or Recognized and covered under ULs Follow-Up Service. Always lood for the Mark on the product. Page 2/10 28March2016/version 0 LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice www.lem.com LEM City answers the demand for an accurate, reliable and easy to install energy sensor for future Smart Cities. www.lemcity.com

Tariff Desc

8504.31.00 TC9500870 TRANSFORMERS, output, ferrite core, frequency within the range 20-50KHz, nominal power rating NOT greater than 100W

8504.31.00 TC1224368 TRANSFORMERS, LED, NOT less than 24VDC and NOT greater than 35VDC

8504.40.30 as follows
(a) separately housed units, designed to be housed in the same cabinet as the central processing unit of equipment of 8471
(b) for telecommunication apparatus of 8517
60 Electric current rectifying assemblies
Free

8504.31.00 TC702370 TRANSFORMERS, CURRENT AND/OR VOLTAGE, having ANY of the following
(a) current transformer voltage rating GREATER than 400kV
(b) voltage transformer voltage rating GREATER than 72kV
(c) combined current and voltage transformer voltage rating GREATER than 72kV

8504.34.00 TC513212 TRANSFORMERS, having ALL of the following
(a) primary and secondary winding
(b) primary voltage NOT less than 500kV
(c) greater than 330 MVA rating

8504.31 TC8343084 AUTOTRANSFORMERS, toroidal core, continuously variable from zero voltage

8504.31 TC8343083 TRANSFORMERS, radio frequency, power rating 100W continuous, frequency range 1.4MHz or greater but NOT exceeding 200.0MHz, input impedance 75ohms, output impedance 50ohms

8504.33.00 TC1761475 CURRENT TRANSFORMER MODULES, with OR without voltage measurement outputs, having NOT greater than 4 poles

8504.31.00 TRANSFORMERS, RF pulse, dual in-line packaging (DIP) TC9209172

8504.31.00 TC 1056338 TRANSFORMERS, TOROIDAL, STEP DOWN, isolated OR auto-wound, enclosed, complying with Australian & NZ Standards AS/NZS61558.1:2008, AS/NZS3820:2009 & AS/NZS3191:2008, including ALL of the following
(a) input voltage NOT less than 230V and NOT greater than 250V
(b) output voltage NOT less than 100V and NOT greater than 120V
(c) female 3 slot output chassis sockets rated at NOT greater than 20A
(d) rated Voltage Amps NOT less than 0.05kVA & NOT greater than 4kVA
(e) thermal fuse or thermal cut out protectors
Beijing Lem
Beijing Lem Electronics
BEIJING LEM ELECTRONICS LTD.
LEM USA Inc.

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON ELECTRONICS
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronic Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing.
All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted