DY (ADY1, 3)
5
Electrical life: Min. 2 10
1a 10A, 1a1b 8A small
DY RELAYS (ADY)
polarized power relays
FEATURES TYPICAL APPLICATIONS
1. Compact size: 1. Control for industrial machines
1 Form A (10A 250V AC), (machine tools, robotics)
1 Form A 1 Form B (8A 250V AC) 2. Output relays for temperature
2. Latching types available controllers, PLCs, timers, sensors.
3. Compliant with IEC EN61010-1. 3. Measuring equipment
Reinforced insulation with 6 mm 4. Security equipment
distance between input and output.
5
4. Electrical life of Min. 2 10 times
(1 Form A type) realized with
inductive load (cos=0.4, L/R=7ms,
5A 250V AC)
5. Sockets are available.
Product name Part No.
Single side stable type DK1a-PS
1 Form A
2 coil latching type DK1a-PSL2
RoHS compliant
Single side stable type DK2a-PS
1 Form A
1 Form B
2 coil latching type DK2a-PSL2
Please see DK relay socket for details.
ORDERING INFORMATION
ADY
Contact arrangement
1: 1 Form A
3: 1 Form A 1 Form B
Operating function
0: Single side stable
2: 2 coil latching type
Auxiliary function
0: Plastic sealed/standard contact
Nominal coil voltage (DC)
03: 3, 05: 5, 06: 6, 09: 9, 12: 12, 24: 24
Note: Certified by UL, CSA and TV
TYPES
Single side stable 2 coil latching
Contact Nominal coil
arrangement voltage
Part No. Part No.
3V DC ADY10003 ADY12003
5V DC ADY10005 ADY12005
1 Form A 6V DC ADY10006 ADY12006
12V DC ADY10012 ADY12012
24V DC ADY10024 ADY12024
3V DC ADY30003 ADY32003
5V DC ADY30005 ADY32005
1 Form A
6V DC ADY30006 ADY32006
1 Form B
12V DC ADY30012 ADY32012
24V DC ADY30024 ADY32024
Standard packing: Carton: 50 pcs.; Case: 500 pcs.
* For sockets, see page 140.
ASCTB182E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/eDY (ADY1, 3)
RATING
1. Coil data
1) Single side stable
Nominal operating
Nominal coil Pick-up voltage Drop-out voltage Coil resistance Nominal operating Max. applied voltage
current
voltage (at 20C 68F) (at 20C 68F) [10%] (at 20C 68F) power (at 20C 68F)
[10%] (at 20C 68F)
3V DC 66.6mA 45
5V DC 40mA 125
70%V or less of 10%V or more of
130%V of
6V DC nominal voltage nominal voltage 33.3mA 180 200mW
nominal voltage
(Initial) (Initial)
12V DC 16.6mA 720
24V DC 8.3mA 2,880
2) 2 coil latching
Nominal operating
Coil resistance Nominal operating
current
Nominal coil Set voltage Reset voltage Max. applied voltage
[10%] (at 20C 68F) power
[10%] (at 20C 68F)
voltage (at 20C 68F) (at 20C 68F) (at 20C 68F)
Set coil Reset coil Set coil Reset coil Set coil Reset coil
3V DC 66.6mA 66.6mA 45 45
5V DC 40mA 40mA 125 125
70%V or less of 70%V or less of
130%V of
6V DC nominal voltage nominal voltage 33.3mA 33.3mA 180 180 200mW 200mW
nominal voltage
(Initial) (Initial)
12V DC 16.6mA 16.6mA 720 720
24V DC 8.3mA 8.3mA 2,880 2,880
2. Specications
Characteristics Item Specications
Arrangement 1 Form A 1 Form A 1 Form B
Contact Contact resistance (Initial) Max. 30 m (By voltage drop 6 V DC 1A)
Contact material Au-ashed AgSnO2 type
Resistive load 10A 250V AC, 10A 30V DC 8A 250V AC, 8A 30V DC
Nominal switching
Inductive load
capacity
5A 250V AC 3.5A 250V AC
(cos = 0.4, L/R = 7ms)
Resistive load 2,500V A, 300W 2,000V A, 240W
Max. switching
capacity
Inductive load
1,250V A 875V A
Rating
(Reference value)
(cos = 0.4, L/R = 7ms)
Max. switching voltage 380V AC, 125V DC
Max. switching current 10 A 8 A
1
Min. switching capacity (Reference value)* 5V 10mA
Nominal operating power 200 mW
Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as Breakdown voltage section.
Between open contacts 1,000 Vrms for 1 min. (Detection current: 10 mA)
Breakdown voltage
(Initial)
Between contact and coil 4,000 Vrms for 1 min. (Detection current: 10 mA)
Surge breakdown
Electrical Between contact and coil 10,000 V
2
voltage* (Initial)
characteristics
Temperature rise (coil) (at70C 158F) Max. 40C (By resistive method, nominal voltage applied to the coil; max. switching current)
Operate time [Set time] (at 20C 68F) Max. 10 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 8 ms [10 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Release time [Reset time] (at 20C 68F)
(without diode)
2
Functional Min. 98 m/s (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Shock resistance
2
Destructive Min. 980 m/s (Half-wave pulse of sine wave: 6 ms.)
Mechanical
characteristics
Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10s.)
Vibration resistance
Destructive 10 to 55 Hz at double amplitude of 3 mm
7
Mechanical Min. 510 (at 300 times/min.)
5
Min. 210 : 1 Form A inductive load (at 20 times/min.) (at rated load);
Expected life
5
Electrical Min. 10 : 1 Form A resistive load,1 Form A 1 Form B resistive load,1 Form A 1 Form B
inductive load (at 20 times/min.) (at rated load)
Ambient temperature: 40C to +70C 40F to +158F;
3
Conditions for operation, transport and storage*
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Conditions
Max. operating speed (at rated load) 20 times/min.
Unit weight Approx. 6g .21oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of 1.250s according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
ASCTB182E 201201-T
Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e