DIN Rail Mount DataSheet HS103DR Series Assemblies 55 amp AC output 40C Single Channel or 3 Phase output 3 to 32 VDC input control voltage DIN Rail mounted UL, CSA, VDE, CE approved SSRs Epoxy free design PRODUCT SELECTION Description 55A 55A 3-32 VDC Control HS103DR-D2490 HS103DR-HD6090 (1) OUTPUT SPECIFICATIONS Description HS103DR-D2490 HS103DR-HD6090 Operating Voltage (47-63Hz) Vrms 24-280 48-660 Transient Overvoltage Vpk 600 1200 Maximum Off-State Leakage Current Rated Voltage mArms 1.0 1.0 Minimum Off-State dv/dt Maximum Rated Voltage V/sec (2) 500 500 Maximum Load Current Arms 55 55 Minimum Load Current Arms 150 150 Maximum Surge Current (16.6ms) Apk 1200 1200 Maximum On-State Voltage Drop Rated Current Vac 1.15 1.15 Maximum It for Fusing (8.3 msec) A sec 6000 6000 Minimum Power Factor (with Maximum Load) 0.5 0.5 (1) INPUT SPECIFICATIONS Description HS103DR-D2490 HS103DR-HD6090 Control Voltage Range 3-32 VDC 4-32 VDC Minimum Turn-On Voltage 3.0 VDC 4.0 VDC Minimum Turn-Off Voltage 1.0 VDC 1.0 VDC Maximum Reverse Voltage -32 VDC -32 VDC Minimum Input Current 7.0 mA 7.0 mA Maximum Input Current 12 mA 12 mA Nominal Input Impeadance Curent Regulated Current Regulated Maximum Turn-On Time msec 1/2 Cycle 1/2 Cycle Maximum Turn-Off Time msec 1/2 Cycle 1/2 Cycle GENERAL SPECIFICATIONS Description HS103DR-Dxx90 Dielectric Strength, Input/Output/Base (50/60Hz) 4000 Vrms 9 Minimum Insulation Resistance ( 500 V DC) 10 Ohms Maximum Capacitance, Input/Output 8 pF Ambient Operating Temperature Range -40 to 80C Ambient Storage Temperature Range -40 to 125C Status Indicator Display None Weight (typical) 1.36 lb. (619 g) Recommended Terminal Screw Torque Range: (in-lbs/Nm) 6-32 Screws - 13-15/1.5-17. 8-32 Screws - 18-20/2-2.2. (Screws dry without grease) Thermal pad installed Yes GENERAL NOTES (1) All parameters at 25C unless otherwise specied. (2) Off-State dv/dt test method per EIA/NARM standard RS-443, paragraph 13.11.1 Do not forget to visit us at: www.crydom.com Copyright 2017 Crydom Inc. Specifications subject to change without notice.DIN Rail Mount DataSheet MECHANICAL SPECIFICATIONS 3.21 3.00 5.20 1.70 3.65 2.37 2.73 1.70 THERMAL DERATE INFORMATION HS103DR w/90A SSR or 1-25A 3-Phase SSR 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 Ambient Temperature (C) AGENCY APPROVALS Designed in accordance with the requirements of IEC 62314 Agency approvals are for relay only. E116949 LR81689 10143 UG (Not Applicable: -B and 4D) Rev. 042413 Do not forget to visit us at: www.crydom.com Copyright 2017 Crydom Inc. Specifications subject to change without notice. Load Current (Amps)