Surge arrester
2-electrode arrester
Series/Type: M50-A260X
Ordering code: B88069X4580C253
Date: 2016-05-23
Version: 03
Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then
change the color towhit. This ensures that the table disappears (invisible) for the customer PDF.
Don't change formatting when entering or pasting text in the table and don't add any cell or line in and to it!
Identification/Classification 1 Surge arrester
(header 1 + top left bar):
Identification/Classification 2 2-electrode arrester
(header 2 + bottom left header bar):
Ordering code: (top right header bar) B88069X4580C253
Series/Type: (bottom right header bar)
M50-A260X
Preliminary data (optional):
Department: PPD AB PD / PPD AB PM
Date: 2016-05-23
Version: 03
EPCOS AG 2016. Reproduction, publication and dissemination of this publication, enclosures hereto and the information
contained therein without EPCOS' prior express consent is prohibited.
EPCOS AG is a TDK Group Company.
Surge arrester B88069X4580C253
2-electrode arrester M50-A260X
Features Applications
Very fast response time Modem
High current rating XDSL-splitter
Stable performance over life Data lines
Very low capacitance Tuner
High insulation resistance Antenna
RoHS-compatible
Electrical specifications
1) 2)
DC spark-over voltage 260 V
Tolerance %
15
Min. V
221
Max. 299 V
Impulse spark-over voltage
at 100 V/s - for 99% of measured values < 700 V
- typical values of distribution < 650 V
at 1 kV/s - for 99% of measured values < 800 V
- typical values of distribution < 700 V
Service life
10 operations 50 Hz, 1 s 5 A
1 operations 50 Hz, 0.18 s (9 cycles) 10 A
10 operations 8/20 s 5 kA
3)
1 operation 8/20 s 10 kA
1 operation 10/350 s 0.5 kA
300 operations 10/1000 s 100 A
Insulation resistance at 100 V > 10
G
DC
Capacitance at 1 MHz < 1.5 pF
Arc voltage at 1 A ~ 10 V
Glow to arc transition current < 0.5 A
Glow voltage ~ 60 V
Weight ~ 1.5 g
Operation and storage temperature C
40 ... +125
Climatic category (IEC 60068-1) 40/125/21
260 YY O
Marking, blue negative
260 - Nominal voltage
YY - Year of production
O - Non radioactive
Certification UL 497B (E163070)
1)
At delivery AQL 0.65 level II, DIN ISO 2859
2)
In ionized mode
3)
After service life DC spark-over voltage may exceed initial values but device will remain in a safe mode
Terms in accordance with ITU-T Rec. K.12, IEC 61663-2 and IEC 61643-311
PPD AB PD / PPD AB PM 2016-05-23
Please read Cautions and warnings and Page 2 of 4