5-30 Watts xppower.com ECL Series Ultra Compact Size Single, Dual & Triple Outputs Open Frame PCB & Chassis Mount Encapsulated PCB Mount Versions <0.3 W No Load Input Power Peak Load Capability 3 Year Warranty Specification Input General Input Voltage 85-264 VAC (120-370 VDC) Efficiency See tables Input Frequency 47-63 Hz Isolation 3000 VAC Input to Output Input Current ECL05: 0.1 A rms, ECL10: 0.2 A rms Switching Frequency 70 kHz typical ECL15: 0.3 A rms, ECL25: 0.4 A rms 3 Power Density ECL05: 2.25 W/In (PCB Mount version) ECL30: 0.8 A rms at 230 VAC 3 ECL10: 5.50 W/In (PCB Mount version) Inrush Current 20 A at 115 VAC, 40 A at 230 VAC, 3 ECL15: 5.30 W/In (PCB Mount version) cold start at 25 C 3 ECL25: 5.90 W/In (PCB Mount version) 3 Earth Leakage Current Class II construction no earth ECL30: 7.10 W/In (PCB Mount version) Power Factor EN61000-3-2, class A MTBF ECL05/10: >450 kHrs, No Load Input Power <0.3 W ECL15/25/30: >400 kHrs, to MIL-HDBK-217F at 25 C, GB Input Protection ECL05/10: Internal T1 A/250 VAC fuse ECL15/25/30: Internal T2 A/250 VAC fuse Environmental Output Operating Temperature -20 C to +70 C, derate linearly from Output Voltage See tables 100% at +50 C to 50% at +70 C Output Voltage Trim 5% on output 1 only, on multiple output Cooling Convection-cooled versions, V2 & V3 will track by same percentage, (not -E or -S versions) Operating Humidity 95% RH, non-condensing Initial Set Accuracy 1% for output 1, Storage Temperature -40 C to +85 C 1% for output 2 of UD01 & UD02 versions, Operating Altitude 3000 m 5% for output 2 & output 3 of other versions Vibration 2 g, 10 Hz to 500 Hz, 10 mins/cycle, Minimum Load Single output versions: none, 60 mins each cycle Multi output versions: UD01 & UD02: 10% V1 & V2 EMC & Safety UD03: 10% V1, 20% V2 UT02 & UT03: 10% V1, 20% V2 & V3 Emissions EN55032, level B conducted & radiated to meet regulation specifications Harmonic Currents EN61000-3-2, class A Start Up Delay 3 s max Voltage Flicker EN61000-3-3 Start Up Rise Time 14 ms max ESD Immunity EN61000-4-2, level 3 Perf Criteria A Hold Up Time 16 ms typical for single output versions, 12 ms typical for multiple output versions, Radiated Immunity EN61000-4-3, 10 V/m 80% mod Perf Criteria A at full load & 115 VAC Line Regulation 0.5% max for single output versions and EFT/Burst EN61000-4-4, level 3, Perf Criteria A output 1 of multiple output versions, Surge EN61000-4-5, installation class 3, 0.9% max for output 2 & output 3 of Perf Criteria A multiple output versions Conducted Immunity EN61000-4-6, 10 Vrms Perf Criteria A Load Regulation 1% max for single output versions, Magnetic Fields EN61000-4-8, 10 A/m, Perf Criteria A for multiple output versions (see note 5) Dips & Interruptions EN61000-4-11, 30% for 10 ms, Cross Regulation Multi output versions only (see note 5) 60% for 100 ms, 100% for 5000 ms Transient Response 4% max deviation, recovery to within Perf Criteria A, B, B 1% in 500 s for a 25% load change Ripple & Noise Single output versions: Safety Approvals IEC60950-1:2005 Ed 2 / IEC62368-1:2014 UL 62368-1 & CAN/CSA C22.2 No. 62368- 3.3-5 V versions: 50 mV pk-pk, 12-15 V versions: 120 mV pk-pk, 1-14, EN62368-1:2014/A11:2017 24-48 V versions: 200 mV pk-pk, Multiple output versions: 1% pk-pk on any output, 20 MHz bandwidth Overvoltage Protection 115-140% Vnom, 195-216% Vnom ECL05/10/15/25 with 3.3 V Overload Protection Single output versions: ECL05/10/15: 120-150%, ECL25: 120-170% of total power Multiple output versions: 140-200% of total power Short Circuit Protection Trip and restart (hiccup mode) Temperature 0.05%/C Coefficient AC-DCAC-DC ECL05/10 Models and Ratings Output Current (2) Output Power Output Voltage Efficiency Model Number (1) Nominal Peak 4.3 W 3.3 VDC 1.30 A 1.69 A 72% ECL05US03 5.0 W 5.0 VDC 1.00 A 1.30 A 75% ECL05US05 5.0 W 9.0 VDC 0.55 A 0.71 A 78% ECL05US09 5.0 W 12.0 VDC 0.41 A 0.54 A 78% ECL05US12 5.0 W 15.0 VDC 0.33 A 0.44 A 80% ECL05US15 5.0 W 24.0 VDC 0.21 A 0.27 A 82% ECL05US24 5.0 W 48.0 VDC 0.10 A 0.13 A 82% ECL05US48 8.6 W 3.3 VDC 2.60 A 3.38 A 72% ECL10US03 10.0 W 5.0 VDC 2.00 A 2.60 A 75% ECL10US05 10.0 W 9.0 VDC 1.10 A 1.43 A 78% ECL10US09 10.0 W 12.0 VDC 0.83 A 1.08 A 78% ECL10US12 10.0 W 15.0 VDC 0.67 A 0.87 A 80% ECL10US15 10.0 W 24.0 VDC 0.42 A 0.55 A 82% ECL10US24 10.0 W 48.0 VDC 0.21 A 0.27 A 82% ECL10US48 Notes 1. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal. 2. Add suffix to model number to define typeO: ad d -P for PCB (-P) mount, add -T for chassis mount, add -E for encapsulated. Mechanical Details Open Frame - PCB Mount (-P) Encapsulated (-E) (-E) (-P) (-P) 0.80 1.95 (20.3) (49.5) 0.91 ACN +Vo (23.0) 0.075 1.00 (-E) (-E) (1.91) (25.4) -Vo ACL 0.40 (10.1) V Adj. 4 x 0.04 (1.0) 0.075 1.80 (1.91) 0.10 (45.7) 0 (2.5) 0.39 (10.0) 1.07 (27.2) 0.90 (22.9) 0.80 0.01 (20.32 0.3) 0.17 0.13 (3.4) (4.4) 0.73 0 0.15 (18.5) (3.8) ACL ACN 0.07 (1.8) (-T) TOP VIEW 0.04 (1.0) 2.06 (52.4) Open Frame - Chassis Mount (-T) T T +Vo -Vo 2.56 (65.0) 4-0.126 (3.20) 0.13 V 0.40 0.01 (10.16 0.3) (3.40) +Vo ACN 1.00 0.68 -Vo (25.4) (17.4) ACL V Adj. 2.28 (58.0) 0.15 0.14 (4.0) (3.5) 0.73 0.85 (18.5) (21.6) Notes Mating Connectors (-T version only) 1. All dimensions in inches (mm). Input Connector: JST PHR-3 2. Weight: ECL05/10 P Version: 0.057 lbs (26 g) Output Connector: JST PHR-2 ECL05/10 T Version: 0.057 lbs (26 g) Crimps: SPH-002T-P0.5S ECL05/10 E Version: 0.13 lbs (60 g) Cable harness with 300 mm wire available, order part no. ECL10 LOOM KIT 3. Tolerances: x.xx = 0.02 (x.x = 0.5) x.xxx = 0.01 (x.xx = 0.25) 1.80 0.01 (45.72 0.3)