3.6kV 36kV High Voltage DIN Distribution Fuses Edison fuses exhibit considerable limitation of current and DIN Dimension Fuses To Specification 2 I t under short-circuit conditions. The stress on circuit DIN 43.625 components is thereby minimized and the reduction of This product group covers current limiting fuses with energy release at the fault reduces fire risks. dimensions to DIN 43.625 and performance in compliance Switching (arc) voltages are appreciably less than with IEC 282-1. permitted values and fall with lower values of recovery Advantages of Edison High Voltage Current - Limiting voltage. The use of, for example, 12kV fuse on 6/7.2kV Fuses systems is therefore permissible. The low power dissipation of Edison fuses ensures low temperature rise of switchgear in which they are Striker Characteristics incorporated. The spring operated striker pin has a travel and energy output in compliance with the requirements of DIN 43625 The elements use the M (metallurgical) effect, similar to and IEC 282-1. that used in low voltage fuses. This ensures that, with melting on long time overloads, excessive temperatures are not reached and damage to switchgear components, such as epoxy encapsulating enclosures, is thus prevented. Recommended Fuse Clipss: Refer to page 122 in this catalog. Fuses that do not employ this feature are not only hotter running by comparison but also usually need to employ a higher current rating of fuse for the same service thus an Edison 40A fuse is equivalent in terms of thermal performance to many other types of 63A rating. Dimensions - Inches (mm) Striker In Operated Position 0.59 15.0mm 1.77 45.0mm Length 1.34 1.02 34.0mm 26.0mm For Diameter and Length Dimensions See Table Above For additional information, visit www.edisonfuse.com 118 Canadian Application Fuse Blocks, Medium Special UL/CSA Fuses UL/CSA Fuses Fuses & Holders Section Holders & Misc. Voltage Fuses Purpose Fuses General Purpose Current Limiting DiameterUL/CSA Fuses Special Canadian Medium Fuse Blocks, Application UL/CSA Fuses General Purpose Purpose Fuses Fuses & Holders Voltage Fuses Holders & Misc. Section Current Limiting 3.6kV 36kV High Voltage DIN Distribution Fuses Circuit Protection Ratings and Dimensions kV Catalog Numbers Amp Ratings Dimensions - in (mm) Diameter x Length IR RMS Sym 3.6ADOSJ(amp) 6.3, 10, 16, 20, 25, 31.5, 40 2.00 x 7.56 (51 x 192) 3.6WDOSJ(amp) 50, 63, 80, 100, 125 2.00 x 7.56 (51 x 192) 3.6WFOSJ(amp) 160, 200 3.00 x 7.56 (76 x 192 3.6 3.6ADLSJ(amp) 25, 40 2.00 x 11.50 (51 x 292) 50kA 3.6WDLSJ(amp) 50, 63, 80, 100, 125 2.00 x 11.50 (51 x 292) 3.6WFLSJ(amp) 160, 200 3.00 x 11.50 (76 X 292) 3.6WKLSJ(amp) 250, 315, 400 3.00 x 11.50 (76 X 292) 7.2TDLSJ(amp) 6.3, 10, 16, 20, 25, 31.5, 40, 50, 63 2.00 x 11.50 (51 x 292) 7.2 7.2TFLSJ(amp) 80, 100, 125, 160 3.00 x 11.50 (76 x 292) 40kA 7.2WKMSJ(amp) 200, 225, 250, 315, 355 3.00 x 17.41 (76 x 442) 12TDLEJ(amp) 6.3, 10, 16, 20, 25, 31.5, 40, 50, 63 2.00 x 11.50 (51 x 292) 12 12THLEJ(amp) 80, 100 2.52 x 11.50 (64 x 292) 63kA 12TKLEJ(amp) 125 3.00 x 11.50 (76 x 292) 12TXLEJ(amp) 160, 200 3.50 x 11.50 (88 x 292) 17.5TDLSJ(amp) 6.3, 10, 16, 20, 25, 31.5, 40 2.00 x 11.50 (51 x 292) 50kA 17.5TFLSJ(amp) 50 3.00 x 11.50 (76 x 292) 35.5kA 17.5 17.5TDMEJ(amp) 6.3, 10, 16, 20, 25, 31.5, 40, 50, 63 2.00 x 17.41 (51 x 442) 17.5THMEJ(amp) 80, 100 2.52 x 17.41 (64 x 442) 50kA 17.5TKMEJ(amp) 125 3.00 x 17.41 (76 x 442) 24TDMEJ(amp) 6.3, 10, 16, 20, 25, 31.5, 40, 50 2.00 x 17.41 (51 x 442) 24 24THMEJ(amp) 63 2.52 x 17.41 (64 x 442) 50kA 24TFMEJ(amp) 80, 100 3.00 x 17.41 (76 x 442) 24TXMEJ(amp) 125, 160 3.46 x 17.41 (88 x 442) 31.5kA 36TDQSJ(amp) 3.15, 6.3, 10, 16, 20, 25 2.00 x 21.16 (51 x 537) 35.5kA 36 36TFQSJ(amp) 31.5, 40, 50 3.00 x 21.16 (51 x 537) 36TXQEJ(amp) 63 3.46 x 21.16 (88 x 537) 20kA Time-Current CharacteristicsAverage For 3.6kV Fuses: 3.6ADOS 3.6WDLS For 7.2kV Fuses: 7.2TDLSJ 3.6WDOS 3.6WFLS 7.2TFLSJ 3.6ADLS 3.6WKLS 7.2WKMSJ CURVES RELATE TO MEAN PRE-ARCING TIME FUSE TYPES: TDL / TFL WITH TOLERANCE 10% ON CURRENT TIME- CURRENT CHARACTERISTIC 4 FOR 7.2kV FUSE-LINKS CURVES RELATE TOMEAN PRE ARCING TIMES WITH A TOLERANCEOF 10% ON CURRENT 10000 HOUR 3 160A 1000 125A 100A 80A 100 63A 50A 40A 10 31.5A 25A 1 20A 16A 10A 10A 6.3A 0.1 6.3A 3.15A* 0.01 10 100 100010000 R.M.S. SYMMETRICAL PROSPECTIVE CURENTINAMPS RMS SYMMETICAL PROSPECTIVE CURRENT IN AMPS * Curve valid for all 3.15A ratings shown in the selection table. Curve valid for all 6.3A ratings shown in the selection table. For additional information, visit www.edisonfuse.com 119 PRE - ARCING TIME IN SECONDS VIRTUAL PRE-ARCING TIME IN SECONDS