CPC1966YX8 Rapid Turn-On INTEGRATED CIRCUITS DIVISION AC Power Switch Description Parameter Rating Units AC Operating Voltage 20 - 240 V CPC1966YX8 is an AC Solid State Switch utilizing rms Continuous Load Current 3 A dual power SCR outputs. This device features Rapid rms Turn-On (non-zero-cross) control of the output SCRs, On-State Voltage Drop 1.1 V (at I = 2A ) P L P which makes it ideal for precisely switching AC loads Typical Turn-On Time 20 s independent of the load voltage phase. Blocking Voltage 800 V P The optically coupled input and output circuits provide 3750V of isolation and noise immunity rms Features between the control and load circuits. As a result, the CPC1966YX8 is well suited for industrial environments Load Current up to 3A rms where electromagnetic interference would disrupt the 800V Blocking Voltage P operation of plant facility communication and control Rapid Turn-On (Non-Zero-Cross Turn-On) systems. Typical Turn-On Time: 20s 5mA Sensitivity Approvals DC Input Switches AC Signal Optically Isolated UL Recognized Component: File E69938 Low EMI and RFI Generation CSA Certified Component: Certificate 1172007 High Noise Immunity Flammability Rating UL 94 V-0 Ordering Information Part Description CPC1966YX8 4-Pin (8-Pin Body) Power SIP Package (25/Tube) Applications Lighting HVAC (Heating, Ventilation, Air Conditioning) Pin Configuration Programmable Control Process Control Power Control Panels Remote Switching R Gas Pump Electronics Contactors Large Relays 1 2 3 4 Solenoids LED + LED AC Load AC Load Motors Heaters Rapid Turn-On (Non-Zero-Cross) Waveforms Control AC Load Voltage Load Current Voltage Across Relay DS-CPC1966YX8-R01 1 www.ixysic.comCPC1966YX8 INTEGRATED CIRCUITS DIVISION Absolute Maximum Ratings 25C Absolute Maximum Ratings are stress ratings. Stresses in Parameter Symbol Ratings Units excess of these ratings can cause permanent damage to Blocking Voltage V 800 V DRM P the device. Functional operation of the device at conditions Reverse Input Voltage V 5V R beyond those indicated in the operational sections of this Input Control Current 50 mA data sheet is not implied. I F Peak (10ms) 1 A Typical values are characteristic of the device at +25C, 1 Input Power Dissipation - 150 mW and are the result of engineering evaluations. They are 2 Total Power Dissipation P 2400 mW D provided for information purposes only, and are not part of 2 i t Fusing Current the manufacturing testing requirements. 2 -8 A s (1/2 Sine Wave, 60Hz) ESD, Human Body Model - 4 kV Isolation Voltage, Input to Output V 3750 V IO rms Operational Temperature T -40 to +85 C A Storage Temperature T -40 to +125 C A 1 Derate linearly 1.33 mW / C 2 Derate linearly 20 mW / C Electrical Characteristics 25C Parameters Conditions Symbol Min Typ Max Units Output Characteristics Load Current, Continuous V =20-240V I 0.1 - 3 A L rms L rms Maximum Surge Current t < 16ms I -- 30 A P Off State Leakage Current V I - - 100 A DRM LEAK P On-State Voltage Drop I =2A - - 0.88 1.1 V L P P Critical Rate of Rise of On-State Current - di/dt - - 75 A/ s Off-State dV/dt - dV/dt 1000 - - V/s Switching Speeds Turn-on I = 5 mA, Resistive Load, V =20V -45 - t s F L on Turn-on -- 20 I = 15 mA, Resistive Load, V =20V F L Turn-off t - - 0.5 cycles off Holding Current - I -44 50 mA H Latching Current - I -48 75 mA L Operating Frequency - 20 - 500 Hz Input Characteristics 1 Input Control Current to Activate -I -- 5 mA F Input Drop-out Voltage - - 0.8 - - V Input Voltage Drop I =5mA V 0.9 1.2 1.4 V F F Reverse Input Current V =5V I -- 10 A R R Common Characteristics Input to Output Capacitance V =0, f=1MHz C -1 - pF IO IO 1 For high-noise environments, or for high-frequency operation, use I > 10mA. F 2 R01 www.ixysic.com